生物兼容三类医疗ISO 10993热塑性弹性体,生物兼容三类医疗ISO 10993 TPE Medalist™ MD-10233 (PRELIMINARY DATA)是东莞市双帮塑胶原料有限公司常年销售的塑料,因为塑料价格行情每天都有新变化前天的报价不等于今天的报价。本公司销售的所有原料保证是原厂原包,随料可以提供生产厂商提供的物性表、SGS报告,COA原料出厂报告,REACH报告,SVHC报告,UL黄卡,提供原料注塑加工工程中可能出现的各种异常现象解决方法,塑料牌号太多,本网站没有提供的本公司也有代理,详情请咨询本公司相关业务人员0769-87795123 13549213581 肖生 QQ:15397858 微信:13549213581
生物兼容三类医疗ISO 10993 TPE, 生物兼容三类医疗TPE
生物兼容三类医疗ISO 10993 TPE, 生物兼容三类医疗TPE, ISO 10993, 生物兼容性, 辐射消毒, 高压锅消毒,环氧乙烷消毒, ISO 13485
Medalist™ MD-10233 (PRELIMINARY
DATA)
热塑性弹性体
Teknor Apex 公司
Technical Data
产品说明
Medalist MD-10233 is a high performance thermoplastic elastomer specifically designed for healthcare and medical applications. Medalist MD-10233 is a low hardness, low density, halogen-free grade that can be sterilized and is suitable for cast films and extrusion.
总览
材料状态 • Preliminary Data 1
资料 2 • Technical Datasheet
搜索 UL 黄卡 • Teknor Apex 公司
供货地区 • 北美洲 • 拉丁美洲 • 亚太地区
• 非洲和中东 • 欧洲
• Low Specific Gravity • 极佳的可印刷性 • 耐化学品性能,良好
• Without Fillers • 抗穿孔性
• 耐磨损性,良好
• 出色的外观 • 良好的加工性能
• 韧性良好
• 低密度 • 良好的拉伸性
特性 • 无卤
• 辐射消毒 • 良好的柔韧性
• 无粘性
• 高弹性 • 良好的着色性
• 硬度,低
• 高压锅消毒 • 良好粘结性
• 有弹性
• 环氧乙烷消毒 • 流动性低
• 薄膜 • 橡胶取代 • 医疗器材
用途 • 流延薄膜 • 牙齿应用领域
• 医疗器械
• 片材 • 医疗/护理用品
机构评级 • ISO 10993 Part 5 • ISO 13485
RoHS 合规性 • RoHS 合规
外观 • 半透明 • 自然色
形式 • 粒子
加工方法 • 挤出 • 流延薄膜
物理性能 额定值单位制 测试方法
密度 / 比重 0.898g/cm³ ASTM D792
熔流率(熔体流动速率) (200°C/5.0 kg) 1.5g/10 min ASTM D1238
弹性体 额定值单位制 测试方法
拉伸应力 4 ASTM D412
100%应变 0.827MPa
300%应变 2.41MPa
抗张强度 4 (断裂) 11.9MPa ASTM D412
伸长率 4 (断裂) 760% ASTM D412
撕裂强度 4 36.8kN/m ASTM D624
压缩永久变形 5 ASTM D395
23°C, 22 hr 12%
70°C, 22 hr 91%
硬度 额定值单位制 测试方法
肖氏硬度 ASTM D2240
邵氏 A, 1 秒, 注塑 35
邵氏 A, 5 秒, 注塑 33
热性能 额定值单位制 测试方法
脆化温度 < -60.0°C ASTM D746
法律声明
The information and recommendations contained in this bulletin are, to the best of our knowledge, accurate and reliable but no guarantee of their accuracy is made. All products are sold upon condition that purchasers shall make their own tests to determine the suitability of such products for their particular purposes and uses and purchaser assumes all risks and liability for the results of use of the products, including use in accordance with seller's recommendations. Nothing in this bulletin constitutes permission or a recommendation to practice or use any invention covered by any patent owned by this company or others. There is no warranty of merchantability and there are no other warranties for the products described. For detailed Product Stewardship information, please contact us. Any product of Teknor Apex, including product names, shall not be used or tested in medical or food contact applications without the prior written acknowledgement of Teknor Apex as to the intended use. Please note that some products may not be available in one or more countries.
Medalist™ MD-10233 (PRELIMINARY DATA)
热塑性弹性体
Teknor Apex 公司
挤出 额定值单位制
料筒 1 区温度 193 到 204°C
料筒 2 区温度 199 到 210°C
料筒 3 区温度 210 到 221°C
料筒 4 区温度 210 到 227°C
口模温度 210 到 227°C
挤压说明
Drying is not necessary. However, if moisture is a problem, dry the pellets for 2 to 4 hours at 150°F (65°C). Screw Speed: 30 to 100 rpm;Screen pack: from 60/200/200/60 to 60/200/400/400/200/60 mesh size
生物兼容三类医疗ISO 10993热塑性弹性体,生物兼容三类医疗ISO 10993 TPE Medalist™ MD-10233 (PRELIMINARY DATA)是东莞市双帮塑胶原料有限公司常年销售的塑料,因为塑料价格行情每天都有新变化前天的报价不等于今天的报价。本公司销售的所有原料保证是原厂原包,随料可以提供生产厂商提供的物性表、SGS报告,COA原料出厂报告,REACH报告,SVHC报告,UL黄卡,提供原料注塑加工工程中可能出现的各种异常现象解决方法,塑料牌号太多,本网站没有提供的本公司也有代理,详情请咨询本公司相关业务人员0769-87795123 13549213581 肖生 QQ:15397858 微信:13549213581
|